Scale basic tutorial, Getting started – Industrial Data Systems IDS Scale Basic User Manual

Page 12

Advertising
background image

Scale Basic 4.2E

Tutorial

Scale Basic Tutorial

The following section assumes that the indicator is connected to a PC computer using EZ Link.
If you are not connected, then use the keyboard entry techniques described in the user’s manual.

Some of the examples used in the tutorial use the TTL Outputs (Relay outputs). Use the
following circuit to view the results of the Relay out commands.

Getting Started

Most instruction books on computer languages start off with the most simple of programs: how
to display “HELLO WORLD” on the computer screen.

Application

Description

Display “HELLO” on the indicators numeric display.

Results / Outputs

HELLO message displayed on numeric display.

Inputs

F1 key to initiate program.

Sequence of operation

Press the F1 key. The indicator displays HELLO.

Use the above design criteria to define the events than need to be configured. The Inputs section
of the design lists the F1 key as the event that starts the Hello program.

Event

Function

Comments

F1 key User Function 1

The F1 key initiates the program by starting function1.

Use the sequence of operation to define User Function 1. The F1 key event triggers a function
that displays “HELLO”. From the list of Scale Basic Instructions we find the Prompt instruction
is used to display messages.

Function

Instructions

Comments

F1:

Instruction

Operand1

Operand2

Operand3

Comment _

Prompt

HELLO Display

HELLO

End

End

of

function

TB4
1

TB2
1

470 ohm

LED

Test Circuit for Relay output 1

+5V

TTL out #1

Advertising