Err 0 Power on acquire zero error. Occurs when parameter 20 is set to acquire zero on power-

up. If the scale is out of zero range or in motion then Err 0 occurs. Remove weight or wait
for stable scale, then press Clear key.

Err 1 Keyboard error. Occurs when a key is pressed while power-on test is in progress.

Err 2 Restart Trap. The microprocessor accessed a non-existent memory location. Usual cause

is electrical noise from the A/C power supply.

Err 3 Watchdog Time-out. The weight display has not been updated within the watchdog time-

out period. Usual cause is A/C power glitch or static electric discharge

Err 4 Battery Error. (Optional) battery voltage level was below 2 V when the indicator was

powered off.

Err 5 EAROM memory error. A checksum error has occurred when reading the configuration

EAROM memory. Check calibration parameters and rewrite the EAROM memory. If
error continues, replace EAROM (U15)

Err 5.1 EAROM Time-out, unable to write to EAROM memory.

Err 6 Ram memory error. Replace U22 if error continues.

Err 7 The A/D converter is "locked up". Check the load-cell wiring.

Err 8 Negative Deadload error.

Err 9 Count-by error. The entered value is not consistent with the configured count-by.

Err 11 A/D converter is not converting.

Err 12 Negative dead-load. Check loadcell wiring.

Err 13 Printer busy error. The busy signal (TB4 pin 14) is active (TTL high).

Err 14 Page Format line length error. A print line exceeded the maximum line length (135 char).

Err 15 The function selected is locked. Switch 2 on the mother board unlocks the parameters.

Err 16 Scale Basic Stack Overflow. Too many nested subroutine calls.

Err 18 Scale Basic Error. A scale basic function attempted to execute an instruction that does

not exits or a Goto/Gosub instruction referenced a non-existent function.

Err 20 Double weigh-in. A weight-in was attempted on an ID that has been weighed-in but not

weighed-out.

Err 21 ID not found.

Err 22 Scale Basic Prompt error. The message length is greater than the display maximum.

Err 23 ID memory full.

Error OL Calibration error or scale is over-loaded.

undEr Calibration error or scale is under-loaded (below readable weight).