Scale Basic 4.2E

Reference

Sign

[r]

207

[r]

Purpose: to set condition codes based on the value in register [r]. Positive is set if the register is

greater than 0, Negative is set if the register is less than 0, Zero is set if the register is zero.

Remarks:

Example: Check for scale below zero.

Sign, Gross

set condition codes using the Gross weight register

If, Negative

If Gross weight < 0

End

Exit

End

if

End

if

Sub

[r] = [a] - [b]

201 [r] [a] [b]

Purpose: subtract register[b] from register [a], put the result into register [r].
Remarks: sets condition codes Positive, Negative, and Zero to reflect results.

Example:

Sub, Memory1, Memory2, Memory3

Memory1 = Memory2 - Memory3

Suspend / Resume

249 / 250

Purpose: Suspend stops a function from executing until a Resume is executed.
Remarks: the Suspend instruction is executed in a scale basic function, the Resume instruction

is executed in an event monitor.


Example: A filling operation stops, waits 4 seconds, then stores the gross weight in Memory1.

Timer 1 is configured for 4 second time-out and execute function Resume.

Timer1: Time:

40

Function: Resume.


Fn. 1: Relay off, 1

turn off fill relay

Timer on, 1

turn on settle timer

Suspend

wait for scale to settle. Timer1 executes Resume

Copy, Memory1, Gross

Memory1 = Gross weight


The above example could use motion detect to wait for scale stable condition.

Set pt 1:

Upper register

False

Lower register

Motion

Execute function

Resume


Fn. 1: Relay off, 1

turn off fill relay

Set pt on, 1

turn on motion detect monitor

Suspend

Setpoint monitor 1 executes Resume

Copy, Memory1, Gross

Memory1 = Gross weight