Resume (see suspend instruction) 250, Set [r] (nnn) 209 [r] [nnn, Set pt off / set pt on (nn) 221 [nn] / 220 [nn – Industrial Data Systems IDS Scale Basic User Manual

Page 31

Advertising
background image

Scale Basic 4.2E

Reference

Relay on, 10

turn relay number contained in Memory10 on


Example: turn off all relays. If scale is at center of zero, turn on relay 3.

Relay off, 0

turn off all relays

If, Centerz

If scale is at center of zero

Relay on, 3

turn on relay 3

End

if

End

if

End

End

of

function

Resume (see Suspend instruction)

250

Set

[r]

(nnn)

209

[r]

[nnn]

Purpose: set a register to a value between 0 and 255.
Remarks: values greater than 255 are replaced by the modulo of 255.

Example:

Set, Memory1, 0

Set,

Tare,

100

Set, Id1, 299

ERROR, the maximum number is 255

Set pt off / Set pt on

(nn)

221 [nn] / 220 [nn]

Purpose: to deactivate / activate a setpoint monitor.
Remarks: the active setpoint monitors are scanned by the event monitor, the inactive setpoint

monitors are not scanned. When the setpoint condition is reached in an active setpoint
monitor, it activates a scale basic function, and de-activates itself. The Set pt on instruction
must be executed to reactivate a setpoint monitor.
Set pt off 0 turns off all setpoint monitors.


Example: a filling operation uses relay output 1 to open a fill valve. Setpoint monitor 1

monitors for overweight conditions, Setpoint monitor 2 is set to activate function 2 when the
net weight on the scale > Memory1. Function key 1 activates function 1 which begins the fill
operation.

Fn1

Get data, Memory1

Get the fill amount

If not, Clear key

If Clear key NOT pressed

Gosub

Tare

Tare

the

scale

Relay on, 1

Turn on fill valve

Set pt on, 1

Turn on over-weight monitor

Set pt on, 2

Turn on setpoint monitor 2

End

if

End

if

End

End

of

function


Fn2

Relay off, 1

Turn off relay1

Set pt off, 0

Turn off all Setpoint monitors

End

End

of

function