Print1, print2, print3, print4 133, 134, 135, 146, Print mode 136, Pulse clear 149 – Industrial Data Systems IDS Scale Basic User Manual

Page 40: Read first 147, Read next 148, Resume 250

Advertising
background image

Scale Basic 4.2E

Reference

Print1, Print2, Print3, Print4

133, 134, 135, 146

Purpose: to send formatted data to the printer.
Remarks: there are 4 pages of print formats that can be configured. Page 1 defaults to print the

Gross weight when the display is in Gross mode, Page 2 defaults to print Gross, Tare, and
Net weights when the display is in the Net mode. Print1 prints page1, Print2 prints page 2,
etc.

Print

mode 136

Purpose: to send formatted print pages to the printer. Send page 1 if the display is in gross

mode, send page 2 if the display is in net mode.

Remarks: this is the default function for the Print key.

Pulse

clear 149

Purpose: set the pulse count register to 0.
Remarks: pulses received on TTL input 6 are counted using the Count register[57]. The

register can be cleared using the Set Pulse, 0 instruction if no counts are being received
instruction is executed. The Pulse clear function is used to guarantee that the register is set
to 0 even if pulses are being received.

Read

first

147

Purpose: read the first ID record in memory. Condition code Positive is true if successful.
Remarks: Open new and Make ID open new ID’s using an ID number (key) to arrange the ID

records in numerical order. Read first reads the ID record with the lowest ID number (key).

Read

next

148

Purpose: read the next ID record in memory. Condition code Positive is true if successful.
Remarks: the Read first / Read next functions are used to scan ID memory from lowest ID to

highest ID. Begin scanning using Read first, then Read next while Positive status is true.


Example
: register Id1 is used for totals. Page format 4 is setup to print ID totals.

Read first

read the first ID in memory

Loop1

While

-

If Positive

Read successful

Gosub

Print4

Print

total

Read next

Read next ID in memory

Next

1

End

-

End

if

While

End

End

of

function

Resume

250

Purpose: used by Setpoints and Timers to resume processing a function that has been

suspended.