Condition codes, Altunits 109, Barcode 111 – Industrial Data Systems IDS Scale Basic User Manual

Page 36: Centerz 104, Clear key 106, Enter key 105, Flag 1…9 51…59

Advertising
background image

Scale Basic 4.2E

Reference

Condition Codes

The condition codes are used in the IF instruction to determine if the instructions following the
IF are to be executed. The arithmetic condition codes are set every time a calculation instruction
is performed. The Setpoint monitor condition codes are true if the monitor corresponding to the
condition code is active. The following table lists the condition codes.

Altunits

109

Purpose: true if display is in alt-units mode.

Barcode

111

Purpose: true if bar-code message has been received on Com Port 1

Centerz

104

Purpose: true if scale is at center of zero

Clear

key

106

Purpose: true if last key pressed was the Clear key
Remarks: the Clear key is used to abort an operation. Test for this key after data entry.
Example:

Get data, Memory1

Get the fill amount

If not, Clear key

If Clear key NOT pressed

Gosub

Tare

Tare

the

scale

Enter

key

105

Purpose: true if last key pressed was the Enter key.
Remarks: the Enter key is used to complete data entry or to continue to the next operation.

Flag

1…9

51…59

Purpose: true if FlagX is ON.
Remarks: the flags are used to remember a state or condition.
Example: Use the F1 key to toggle the display between Net display mode and Total (Memory1)

display mode. Flag 1 is set ON to display Total, Off to display Gross.

Fn. 1: If, Flag1

if Flag1 is on (ON = display total)

Display, Gross

set display mode to gross weight

Else

else (Flag is off = display gross)

Display, Memory1

set display mode to total weight

End

if

End

if

Advertising