9. FUNCTIONS

The scale has Function settings to expand your applications.
The parameters set in the Function settings are maintained even if the power switched
off.





9-1. The procedure for setting parameters

1. Turn the power off.

2. Press and hold the ZERO switch and turn the

power on via the ON/OFF switch. Then, the first
function item and its parameter is displayed.

3. Set the parameter value using the PRINT switch.

? If you do not need to change the parameter, go to next

step without setting.

4. Press the MODE switch. Then the display goes to

the next function item.

? In this stage, the new parameter is not stored in

the scale yet.

? To end changing the parameters, turn the power

off.

5. Repeat the steps 3 and 4 to the last item.

6. After setting the last item, press the MODE switch,

Then, end will appear.

7. Press the MODE switch again. The parameters are

stored in the scale, and the scale will automatically boot
up.

? If you turn the power off before this step is done,

none of the parameters will be changed.










f 1- 1

f 1- 1

Item

Parameter

f 1- 0

f 2- 1

end

888