9-2. Function list

Item

Description

f 1- 0

Auto power-off disabled

? f 1- 1

Auto power-off enabled for battery
use only

Auto power-off
function

f 1- 2

Auto power-off enabled for battery
and AC adapter

Automatically
power off

f 2- 0

Normal (1/3,000 class)

? f 2- 1

High (1/6,000~1/7,500 class)

Display
resolution

f 2- 2

Higher (1/12,000~1/15,000 class)

Legal for trade

will be Normal.

? f 3- 0

lb

f 3- 1

oz

Weighing unit
when powered
on

f 3- 2

kg

U.S.A. models
only

? f 4- 0

2400 bps

f 4- 1

4800 bps

RS-232C
Baud rate

f 4- 2

9600 bps

? f 5- 0

Stream mode

f 5- 1

Command mode

f 5- 2

Print switch mode

f 5- 3

Auto-print mode +/- data

RS-232C
Data output
mode

f 5- 4

Auto-print mode + data

? f 6- 0

Comparator disabled

f 6- 1

Compares all data

f 6- 2

Compares data > +4d or < -4d

f 6- 3

Compares all stable data

Comparator
mode

f 6- 4

Compares stable data > +4d or < -4d

Conditions to
compare.
d = minimum
display division

f 7- 0

Weak / fast response

? f 7- 1

Normal / normal response

Filtering to
weighing data

f 7- 2

Strong / slow response

? f 8- 0

Reply is sent

RS-232C
Data format

f 8- 1

No reply except “Q” command

Reaction to the
command

? Factory setting