Data output mode

? Stream mode Function setting “F5-0”

The scale outputs the current display data. The data-update rate is approximately 10
times per second. This rate is the same as the display-update.
The scale does not output data while it is in setting mode.


? Print switch mode Function setting “F5-2”

When the PRINT switch is pressed while the weighing data is stable (STABLE
indicator is on), the scale transmits the data.


? Auto-print mode +/- data Function setting “F5-3“

The scale transmits the weighing data when the display is stable (STABLE indicator
is on) and the data is more than +4d or less than -4d of weight data.

d = minimum weight display (see “12-1 Specifications”)
When in counting mode, “d” is equal to minimum weight display of kg mode.

The next output can be obtained after the display returns to between -4d and +4d.


? Auto-print mode + data Function setting “F5-4“

The scale transmits the weighing data when the display is stable (STABLE indicator
is on) and the data is more than +4d of weight data.

d = minimum weight display (see “12-1 Specifications”)
When in counting mode, “d” is equal to minimum weight display of kg mode.

The next output can be obtained after the display returns to below +4d.

? Command mode Function setting “F5-1

In the command mode, the scale is controlled by commands that come from the
personal computer and so on.


Command list

“Q” command

Command to request the current weighing data.

Command

Q C

R

L

F

Reply

S T , + 0 0 1 2 3 . 4 5 _ k g C

R

L

F

“Z” command

Same operation as the RE-ZERO or ZERO switch.

Command

Z C

R

L

F

? This command works as RE-ZERO for the metric models

and as ZERO for U.S.A. models.

“T” command

Same operation as the TARE switch.

Command

T C

R

L

F

? This command works as TARE for U.S.A. models.
? The metric models cannot accept this command.


Advertising
This manual is related to the following products: