IMPORTANT

Prior to removing the igniter-injector, note the position of the gas injector
tube relative to the burner plate and blower. This is necessary to ensure
that the igniter injector is reinstalled in the proper orientation when it is
reconnected to the staged ignition assembly.

STAGED

IGNITION

ASSEMBLY

FLAME
DETECTOR

IGNITOR-

INJECTOR

BURNER

PLATE

COMPRESSION

FITTING & ELBOW

FLAME
DETECTOR
GASKET

INDEXING

WASHERS

(QTY = 0-3

AS REQ’D)

Figure 7-2: Igniter-Injector & Flame Detector Mounting Details

5. Next, loosen and remove the igniter-injector from the burner plate using a 1" open-end

wrench.

6. Check the igniter-injector for evidence of erosion or carbon build-up. If there is evidence of

substantial erosion or carbon build-up, the igniter-injector should be replaced. If carbon
build-up is present, clean the component using fine emery cloth. Repeated carbon build-up
is an indication that the combustion settings of the unit should be checked. Refer to Chapter
4 for combustion calibration procedures.

7. Prior to reinstalling the igniter-injector, a high temperature, conductive, anti-seize compound

must be applied to the threads.

NOTE

If a replacement igniter-injector (part no. 58023) is being installed, a
compression nut containing a built-in ferrule will be included with the
replacement part. If needed, three indexing washers are also included
These washers may be needed to properly position the gas injector tube of
the igniter-injector within the 120° angle range shown in Figure 7-3.