15
Boiler Mounting
• Locate the general area of the boiler place-
ment.
• Place the wall-mounting bracket on the
wall ensuring the upper edge of the brack-
et is away from the wall.
• Level the bracket and use a pencil to mark
the location of the mounting slots on the
wall.
• Remove the bracket from the wall and drill
a 5/8” diameter hole by 1-3/8” deep posi-
tioned in the center of each mark.
• Install the anchors (provided) fl ush or
slightly recessed in the drilled holes with
threaded side facing down.
• Reposition the bracket on the wall and
align mounting slots/holes. Insert the two
bolts (provided) through the mounting
slots/holes and loosely tighten.
• Level bracket and tighten bolts securely.
Boiler Mounting
• Obtain assistance in lifting the boiler onto
the wall bracket.
• Install the boiler making sure the boiler
mounting lip located along the upper edge
of the rear jacket panel engages the wall-
mounting bracket. Ensure the boiler is
seated properly and is secure.
GF-125