Installation, Wiring instructions – American Access Systems Touch Plate Reader - 11-3500 User Manual

Page 10

Advertising
background image

Page 10 American Access Systems / Security Brands, Inc.

Installation

Wiring Instructions

The 11-3500 is provided with a connector and 10 wire leads (see figure 2). Using appropriate wire nuts or crimp on
connectors, wire the unit as per table 1 below. Be sure unused wires are insulated to avoid shorting. In addition to the
wiring below, and on following page, AN EARTH GROUND IS REQUIRED.

Wire

Color

Description

1

White

10 to 24 ac

or 10 to 24 dc

2

White

3

Yellow

Normally Open *

4

N/A

Not Used

5

Green

Common

6

N/A

Not Used

7

Red

8 VDC for SecuraRelay™

8

N/A

Not Used

9

Orange

Remote Open

10

Brown

Remote Open

* Can be reprogrammed as Normally Closed, See page 10