Typical Installation for 11-3500 to Gate

Operator

Gate Operator

4 Conductor Shielded

Cable

12 VAC

xformer

Open

Circuit

Power

Can Be Plugged into

a outlet installed

inside Gate Operator

Terminals located on

operator control

board.

White night light leads will hook directly to power leads when using 12 VAC transformer. If using 24VAC

operator control voltage you MUST connect a 100 ohm 10 watt resistor in series with on of the white

night light leads to reduce voltage to 12 volts

See Table 1 on page

10 for proper wire

connections to card

reader harness