Specifications – American Access Systems Touch Plate Reader - 11-3500 User Manual

Page 12

Advertising
background image

Page 12 American Access Systems / Security Brands, Inc.

NEW FEATURES AVAILABLE ON

11-3500 VERSION 4.0 AND LATER.

REMOTE OPEN (REX)

Connect the Brown and orange wires to any Normally Open switch. Closing this circuit will activate the latch Relay/
Shunt Relay for the number of seconds you have selected when you set the Latch Timer.

SecuRelayTM

The SecuRelayTM from Secura Key may be purchased separately for use with ENTRACOMP® 26SA units which
have firmware version 4.0 or later. SecuRelayTM allows the lock/gate control circuit to be remotely located so that
attacking the 26SA will not open the passageway. SecuRelayTM comes with a wiring harness which plugs directly
into the 3-pin header on the 26SA circuit board (see figure 1) NOTE: Remote Open must be disabled if SecuRelayTM
is used.

SOLID STATE RELAY (Version 4.05).

See page 10 for programming the NEW solid state relay.

SPECIFICATIONS

POWER REQUIREMENTS

10 to 24 VAC, 70 mA , 50 or 60 Hz or 10 to 24 VDC, 70mA

OUTPUTS

Latch & Alarm Shunt

SPST contact, 1A up to 60 VAC or VDC

Tamper (optional)

SPDT contact, 115 VAC, 2A maximum

SecuRelayTM (optional)

3-wire data and power circuit

INPUTS

Remote Open (REX)

Close circuit to operate Latch Relay

ENVIRONMENT

Ambient Temperature

-40oF to 158oF (-40oC to 70oC)

Humidity

0% to 95% relative humidity (non-condensing)

OPERATIONAL

Memory

E² PROM (non-volatile)

Card Capacity

65,503 cards

Facility Code

Up to 10 different codes simultaneously

Latch/Alarm Shunt Timer

Programmable from 1 to 99 seconds

Timed Antipassback

Programmable from 1 to 99 minutes

This product complies with UL 294 standards.
TouchCard® and SecuRelay™ are trademarks of Secura Key.

Advertising