Relay configuration – American Access Systems Touch Plate Reader - 11-3500 User Manual

Page 9

Advertising
background image

Page 9 American Access Systems / Security Brands, Inc.

Relay Configuration

The solid-state relay can be set to be Normally Closed, Normally Open or to operate with the SecuRelay™ for
increased vandal resistance.
Selections are:
Normally Open (Factory default)
Normally Closed
SecuRelay™ Option.
The default mode is Normally Open (NO).
To place the relay in the Normally Open (NO) mode, place the “*” card on the reader twice, followed by the “6”
card.

* + * + 6

To place the relay in the Normally Closed (NC) mode, place the “*” card on the reader twice, followed by the “7”
card.

* + * + 7

To place the unit in the SecuRelay™ mode, place the “*” card on the reader twice, followed by the “8” card.

* + * + 8

To return to normal mode, place the “*” card on the reader twice followed by the “1” card.

Advertising