Dam514 – Ecler CA‐NET RS‐232 User Manual

Page 19

Advertising
background image

 

 

CA‐NET Protocol

 

page  19 / 29 

 

DAM514

 

TYPE 

PARAM1 

PARAM2 

PARAM3 

PARAM4  DESCRIPCIÓN 

GET 

ALL

 

 

 

 

 

Dumps current device status (with DATA messages) 

 

INFO_MODEL 

 

 

 

Gets the Device model name  

 

INFO_VERSION 

 

 

 

Gets the current Firmware Version 

 

AUTOLOAD_PRESET1 

 

 

 

Gets the current AUTOLOAD_PRESET1 at Startup function 

 

PRESET_NUMBER 

 

 

 

Gets the current PRESET number 

 

PRESET_NAME 

<Preset=P1:P10> 
<Preset=T1:T6> 

 

 

Gets a certain PRESET (from P1 to P10) or TEMPLATE (from T1 to T6) 
name 

 

REMOTE_MODE 

<Remote=R1:R4> 

 

 

Gets the working mode for a certain REMOTE port (from R1 to R4) 

 

REMOTE_INPUTS 

<Remote=R1:R4> 

 

 

Gets the list of inputs affected by the working mode of a certain 
REMOTE port (from R1 to R4)  

 

REMOTE_ZONES 

<Remote=R1:R4> 

 

 

Gets the list of outputs affected by the working mode of a certain 
REMOTE port (from R1 to R4) 

 

DISPLAY_MODE 

 

 

 

Gets the current LCD DISPLAY MODE 

 

LCD_CONTRAST 

 

 

 

Gets the current LCD DISPLAY CONTRAST level 

 

EXT_MUTE_ZONES 

 

 

 

Gets the outputs to be muted by an external contact closure, 
connected to the MUTE port 

 

IN_LABEL 

<Input=I1:I5> 

 

 

Gets the current LABEL (name) for the specified INPUT 

 

IN_STEREO 

<Input=I4:I5> 

 

 

Gets the current STEREO link status (ON or OFF) for INPUTs 4 and 5 

 

IN_MUTE 

<Input=I1:I5> 

 

 

Gets the current MUTE status (ON or OFF) for the specified INPUT 

 

IN_VOL 

<Input=I1:I5> 

 

 

Gets the current VOLUME for the specified INPUT (general input 
volume, affecting all the post processing) 

 

IN_BASS 

<Input=I1:I5> 

 

 

Gets the current BASS tone LEVEL for the specified INPUT 

 

IN_MID 

<Input=I1:I5> 

 

 

Gets the current MIDDLE tone LEVEL for the specified INPUT 

 

IN_TREBLE 

<Input=I1:I5> 

 

 

Gets the current TREBLE tone LEVEL for the specified INPUT 

 

HPF_ACTIVE 

<Input=I4:I5> 

 

 

Gets the current HIGH PASS FILTER status (ON or OFF) for the specified 
INPUT 

 

HPF_FREQUENCY 

<Input=I4:I5> 

 

 

Gets the current HIGH PASS FILTER frequency (Hz) for the specified 
INPUT 

 

FBS_ACTIVE 

<Input=I4:I5> 

 

 

Gets the current FEEDBACK SUPPRESSOR feature status (ON or OFF) 
for the specified INPUT 

Advertising