Ecler CA‐NET RS‐232 User Manual
Page 27

CA‐NET Protocol
page 27 / 29
specified INPUT
TALKOVER_RELEASE
<Input=I4:I5>
<ReleaseTime=msx10>
Shows the current TALKOVER RELEASE TIME (milliseconds x10) for
the specified INPUT
CHIME_MELODY
<Input=I4:I5>
<ChimeMelody>
Shows the current CHIME MELODY selected for the TALKOVER
function in PAGER mode
CHIME_VOL
<Input=I4:I5>
<Volume=dBx10>
Shows the current CHIME VOLUME (dBx10) adjusted for the
TALKOVER function in PAGER mode
XSELECT
<Input=I1:I5>
<Zone=ZA:ZD>
ON/OFF
Shows the current CROSSPOINT SELECT status (ON (input active) or
OFF (input muted)) for the specified INPUT at the specified output
zone
XLEVEL
<Input=I1:I5>
<Zone=ZA:ZD>
<Level=0:99>
Shows the current CROSSPOINT LEVEL (mix level) for the specified
INPUT at the specified output zone
ZONE_LABEL
<Zone=ZA:ZD>
“<Label>”
Shows the current LABEL (name) for the specified output zone
ZONE_STEREO
<Zone=ZA:ZD>
ON/OFF
Shows the current STEREO link status (ON or OFF) the specified
output zone
ZONE_MUTE
<Zone=ZA:ZD>
ON/OFF
Shows the current MUTE status (ON or OFF) for the specified
output zone
ZONE_VOL
<Zone=ZA:ZD>
<Volume=0:99>
Shows the current VOLUME for the specified output zone
GEQ_ACTIVE
<Zone=ZA:ZD>
ON/OFF
Shows the current GRAPHICAL EQUALIZER status (ON or OFF) for
the specified output zone
GEQ_GAIN
<Zone=ZA:ZD>
<Band=B1:B10>
<Gain=dBx10> Shows the current GAIN (dBx10) of one BAND (B1 to B10) of the
GRAPHICAL EQUALIZER for the specified output zone
XOVER_ACTIVE
<Zone=ZA:ZD>
ON/OFF
Shows the current CROSSOVER FILTER status (ON or OFF) for the
specified output zone
XOVER_TYPE
<Zone=ZA:ZD>
LP/HP
Shows the current CROSSOVER FILTER TYPE (LP or HP) for the
specified output zone
XOVER_FREQUENCY
<Zone=ZA:ZD>
<Frequency=Hz>
Shows the current CROSSOVER FILTER FREQUENCY (Hz) for the
specified output zone