CA‐NET Protocol

 

page  2 / 29 

 

GET 
SET 
DATA 
ERROR 

At  the  end  of  this  document  you’ll  find  a  table  including  all  the  available  messages  and  their 
parameters for each model of CA‐NET compatible device. 

The

 GET 

&

 SET

 messages can be sent from the client (control system) to the CA / DAM device. The 

DATA 

ERROR

 messages can just be sent from the CA / DAM device to the client.  

The 

SET

 messages coming from a client device don’t have an automatic acknowledgement with a 

DATA

 message sent from the CA / DAM device after it has processed the 

SET

 command. The client 

must  update  the  values  itself,  sending  the  needed 

GET

  message  to  ask  for  a  parameter’s  value 

when it requires confirmation from the device. On the other hand, when a local control in the CA / 
DAM unit occurs (for instance, using the front panel controls or an infrared remote control), the CA 
/  DAM  device  will  automatically  send  the  associated 

DATA

  command  via  its  RS‐232  interface,  to 

keep synchronisation with the client device.  

 

CA40 and CA200z NOTES: 

 A  couple  of  special  parameters  for  the 

GET

  and 

SET

  commands  would  require  a  detailed 

explanation: 

1.

AUTOLOAD_PRESET1

:  its  value  (ON/OFF)  defines  whether  preset  number  1  must  be 

recalled  or  not  each  time  the  CA  device  is  powered  ON,  defining  this  way  the  default 
working mode at startup 

2.

PANEL_LOCKED

: its value (ON/OFF) defines whether the front panel controls (the rotary 

encoder in the case of the CA40, and the encoder and the function keys in the case of 
the CA200z) is enabled (PANEL_LOCKED=OFF) or disabled (PANEL_LOCKED=ON) for local 
management of the device. (see the CA40 or CA200z user manual for further details) 

 The numerical values are always integer numbers without 

comma

 or 

dot

 symbols 

<Input  Name>

 

are  text  strings  (without  blank  spaces)  that  identify  an  audio  input  of  a  CA 

device: 

For the CA40, there are 5 possible Input Names: 

o

LINE1 

o

LINE2 

o

MICRO 

o

LINE1_AND_MICRO 

o

LINE2_AND_MICRO 