CA‐NET Protocol

 

page  4 / 29 

 

o

OFF 

o

INPUTS 

o

PRESETS 

 

In the CA40, a single REMOTE port admits the connection of a WPmVOL‐SR unit, which 
has a volume control knob and a 5‐position rotary switch, or selector. The selector can 
be used in any of these two modes: 

o

INPUTS:  to  select  the  active  audio  source(s)  (LINE1,  LINE2,  MICRO, 
LINE1_AND_MICRO or LINE2_AND_MICRO) 

o

PRESETS: to recall any of the 5 presets in the memory of the unit, which store the 
full configuration of the unit, including volumes, EQ, etc. 

The factory default working mode of the selector is INPUTS, and it can just be modified 
to PRESETS by means of an RS‐232 connection. 
 
In the CA200z there are two independent REMOTE ports, each one able to control one of 
the device’s outputs when the CA200z has been configured in the ZONES A/B mode. Each 
selector can be used in any of these 3 modes: 

o

INPUTS: to select the active audio LINE source (OFF, LINE1, LINE2,  LINE3 or LINE4) 

o

PRESETS: to recall any of the 5 presets in the memory of the unit, which store the 
full configuration of the unit, including volumes, EQ, etc. Just one out of these two 
remote ports can be configured to recall presets, not both at the same time 

o

OFF: REMOTE port disabled. 

 

<Zone>

 are text strings (without blank spaces) that identify a zone where the command will 

operate. In the CA200z there are just two possible values for this parameter: 

o

ZA (output labeled as ZA or L) 

o

ZB (output labeled as ZB or R) 

When the <Zone> parameter is not specified, the CA200z will understand the command will 
operate over ZA. 

<Micro  Name>

 

are  text  strings  (without  blank  spaces)  that  identify  the  MIC  inputs  in  the 

unit. In the CA200z there are just two possible values for this parameter: 

o

MICRO1 

o

MICRO2 

<Output Mode>

 are text strings (without blank spaces) that identify the amplifier’s output 

working mode. In the CA200z there are just four possible values for this parameter: 

o

STEREO 

o

MONO 

o

BRIDGE 

o

ZONES 

<Zone Label>

 is a text string that contains the customized name for a zone that the CA200z 

will  show  in  its  LCD  display.  The  maximum  length  for  this  string  is  17  characters,  being 