CA‐NET Protocol

 

page  23 / 29 

 

volume, affecting all the post processing) 

 

IN_BASS 

<Input=I1:I5> 

<Gain=dBx10> 

 

Sets the current BASS tone LEVEL for the specified INPUT 

 

IN_MID 

<Input=I1:I5> 

<Gain=dBx10> 

 

Sets the current MIDDLE tone LEVEL for the specified INPUT 

 

IN_TREBLE 

<Input=I1:I5> 

<Gain=dBx10> 

 

Sets the current TREBLE tone LEVEL for the specified INPUT 

 

HPF_ACTIVE 

<Input=I4:I5> 

ON/OFF 

 

Sets the current HIGH PASS FILTER status (ON or OFF) for the 
specified INPUT 

 

HPF_FREQUENCY 

<Input=I4:I5> 

<Frequency=Hz> 

 

Sets the current HIGH PASS FILTER frequency (Hz) for the specified 
INPUT 

 

FBS_ACTIVE 

<Input=I4:I5> 

ON/OFF 

 

Sets the current FEEDBACK SUPPRESSOR feature status (ON or OFF) 
for the specified INPUT 

 

GATE_ACTIVE 

<Input=I4:I5> 

ON/OFF 

 

Sets the current NOISE GATE status (ON or OFF) for the specified 
INPUT 

 

GATE_THRESHOLD 

<Input=I4:I5> 

<Threshold=dBx10> 

 

Sets the current NOISE GATE THRESHOLD LEVEL (dBx10) for the 
specified INPUT 

 

GATE_DEPTH 

<Input=I4:I5> 

<Depth=dBx10> 

 

Sets the current NOISE GATE DEPTH (attenuation when gate is 
closed, dBx10) for the specified INPUT 

 

GATE_ATTACK 

<Input=I4:I5> 

<AttackTime=msx10> 

 

Sets the current NOISE GATE ATTACK TIME (milliseconds x10) for 
the specified INPUT 

 

GATE_HOLD 

<Input=I4:I5> 

<HoldTime=msx10> 

 

Sets the current NOISE GATE HOLD TIME (milliseconds x10) for the 
specified INPUT 

 

GATE_RELEASE 

<Input=I4:I5> 

<ReleaseTime=msx10>   

Sets the current NOISE GATE RELEASE TIME (milliseconds x10) for 
the specified INPUT 

 

TALKOVER_ACTIVE 

<Input=I4:I5> 

ON/OFF 

 

Sets the current TALKOVER status (ON or OFF) for the specified 
INPUT 

 

TALKOVER_MODE 

<Input=I4:I5> 

PAGER/DUCKER 

 

Sets the TALKOVER function working mode (PAGER or DUCKER) for 
the specified INPUT 

 

TALKOVER_PRIORITY 

<Input=I4:I5> 

LOW/HIGH 

 

Sets the current TALKOVER PRIORITY level (LOW or HIGH) for the 
specified INPUT 

 

TALKOVER_ZONES 

<Input=I4:I5> 

<Zones=ZA:ZD> 

 

Sets the current TALKOVER assignment to outputs (ZONES) for the 
specified INPUT. Zones parameter can include ZA to ZD, separated 
by comma characters and no blank space (example:  ZA,ZC,ZD) 

 

TALKOVER_THRESHOLD 

<Input=I4:I5> 

<Threshold=dBx10> 

 

Sets the current TALKOVER THRESHOLD LEVEL (dBx10) for the 
specified INPUT 