Ecler CA‐NET RS‐232 User Manual

Page 22

Advertising
background image

 

 

CA‐NET Protocol

 

page  22 / 29 

 

 

TYPE  PARAM1 

PARAM2 

PARAM3 

PARAM4 

DESCRIPCIÓN 

SET 

AUTOLOAD_PRESET1 

ON/OFF 

 

 

Sets the current AUTOLOAD_PRESET1 at Startup function 

PRESET_NUMBER 

<Preset=P1:P10> 
<Preset=T1:T6> 

 

 

Sets (loads) the current PRESET number 

 

LOAD_PRESET 

<Preset=P1:P10> 
<Preset=T1:T6> 

 

 

Sets (loads) the current PRESET number (same function as 
PRESET_NUMBER) 

 

SAVE_PRESET 

<Preset=P1:P10> 

“<Name>” 

 

Saves the current configuration into a certain PRESET position (from 
P1 to P10) and with a certain LABEL, or name (between quotation 
marks to allow for blank characters in the label) 

 

REMOTE_MODE 

<Remote=R1:R4> 

<RemoteMode> 

 

Sets the working mode for a certain REMOTE port (from R1 to R4). 
Valid working modes are: DISABLED, IN_VOL, ZONE_VOL, IN_SEL, 
IN_SEL_IN_LEVEL, IN_SEL_ZONE_VOL, PRESET, PRESET_ZONE_VOL 

 

REMOTE_INPUTS 

<Remote=R1:R4> 

<Inputs=I1:I5> 

 

Sets the list of inputs affected by the working mode of a certain 
REMOTE port (from R1 to R4). Inputs parameter can include I1 to I5, 
separated by comma characters and no blank space (example:  
I1,I2,I3) 

 

REMOTE_ZONES 

<Remote=R1:R4> 

<Zones=ZA:ZD> 

 

Sets the list of outputs affected by the working mode of a certain 
REMOTE port (from R1 to R4). Zones parameter can include ZA to 
ZD, separated by comma characters and no blank space (example:  
ZA,ZC,ZD) 

 

DISPLAY_MODE 

<DisplayMode> 

 

 

Sets the current LCD DISPLAY MODE (NORMAL or DIMMED or OFF) 

 

LCD_CONTRAST 

<Contrast=0:100> 

 

 

Sets the current LCD DISPLAY CONTRAST level 

 

EXT_MUTE_ZONES 

<Zones=ZA:ZD> 

 

 

Sets the list of outputs to be muted by an external contact closure, 
connected to the MUTE port. Zones parameter can include ZA to 
ZD, separated by comma characters and no blank space (example:  
ZA,ZC,ZD) 

 

IN_LABEL 

<Input=I1:I5> 

“<Label>” 

 

Sets  the  current  LABEL  (name)  for  the  specified  INPUT  (between 
quotation marks to allow for blank characters in the label) 

 

IN_STEREO 

<Input=I4:I5> 

ON/OFF 

 

Sets the current STEREO link status (ON or OFF) for INPUTs 4 and 5 

 

IN_MUTE 

<Input=I1:I5> 

ON/OFF 

 

Sets the current MUTE status (ON or OFF) for the specified INPUT 

 

IN_VOL 

<Input=I1:I5> 

<Volume=0:99> 

 

Sets the current VOLUME for the specified INPUT (general input 

Advertising