“SPECIAL CYCLES” FUNCTION

10.1

Preliminary notes

The “Special cycles” function allows to use the work cycles

made available by EVCO.

One of the following work cycles can be started:

-

core regeneration cycle (only if the needle probe is

enabled, i.e. if parameter P2 is set at 1)

-

timed regeneration cycle

-

timed proving cycle

-

environment cooling cycle.

The following table illustrates the factory settings of the core

regeneration cycle.

SETTING

DEFAULT

MINIMUM...

MAXIMUM

work set-point

110 °C

20... 180 °C

humidification

70 %

40... 100 %

core set-point

70 °C

20... 100 °C

fan speed

minimum

vent opening

on conclusion of the cycle

The following table illustrates the factory settings of the timed

regeneration cycle.

SETTING

DEFAULT

MINIMUM...

MAXIMUM

work set-point

110 °C

20... 180 °C

humidification

70 %

40... 100 %

duration of the

phase

25 min

1... 90 min

fan speed

minimum

vent opening

on conclusion of the cycle

The following table illustrates the factory settings of the timed

proving cycle.

SETTING

DEFAULT

MINIMUM...

MAXIMUM

work set-point

30 °C

20... 50 °C

humidification

80 %

40... 100 %

duration of the

phase

120 min

1... 300 min

fan speed

minimum

vent opening

on conclusion of the cycle

The following table illustrates the factory settings of the

environment cooling cycle; the opening and closing of the door

does not cause any consequence.

SETTING

DEFAULT

MINIMUM...

MAXIMUM

work set-point

50 °C

(param. r11)

0... 500 °C

fan speed

maximum, without inversion of

rotation direction (if envisioned)

vent opening

at the start of the cycle, for the

entire duration of the same