EVCO EVCSR338J9 User Manual
Page 35

EVCO S.p.A.
Vcolor 338 S | Installer manual ver. 1.2 | Code 144VC338SE124
page 35 of 50
r7 0 r8
°C/°F
(2)
0
Delta T set-point minimum (referring to the temperature detected by
the needle probe)
r8 r7 150
°C/°F
(2)
30
Delta T set-point maximum (referring to the temperature detected
by the needle probe)
r9 r7 r8
°C/°F
(2) 5
Delta T set-point for factory setting (referring to the temperature
detected by the needle probe)
r10 -199 199 °C/°F
(2) 10
work set-point during preheat (relative to the work set-point during
the first phase of the cooking cycle, i.e. “work set-point during the
first phase of the cooking cycle + r10”; referring to the temperature
detected by the environment probe); see also parameter r0
r11 0 500
°C/°F
(2)
50
work set-point during cooling (referring to the temperature detected
by the environment probe)
r12
0
240
min
240
duration of a power supply cut-off (3)
PARAM.
MIN.
MAX.
U.M.
DEF.
VARIOUS
c0 -1 120 s
10
duration of buzzer activation on conclusion of the cooking cycle
-1 = as long as it is silenced by hand
c1
0
1
- - -
0
activation of the buzzer (for 1 s) on conclusion of a cooking cycle
phase
c2 0 240 min 60
time that must pass without operations on the device (from
activation of the “Weekly programmed switch-on”) until this
switches off
c3 0 99
°C/°F
(2)
10
temperature over which the display of the temperature detected by
the environment probe is blocked (relative to the work set-point, i.e.
“work set-point + c3”)
0 = function
absent
c4 0 99
°C/°F
(2)
10
temperature above which the display of the temperature detected by
the environment probe is blocked (relative to the work set-point, i.e.
“work set-point - c4”)
0 = function
absent
PARAM.
MIN.
MAX.
U.M.
DEF.
FAN