EVCO EVCSR338J9 User Manual

Page 35

Advertising
background image

EVCO S.p.A.

Vcolor 338 S | Installer manual ver. 1.2 | Code 144VC338SE124

page 35 of 50

r7 0 r8

°C/°F

(2)

0

Delta T set-point minimum (referring to the temperature detected by

the needle probe)

r8 r7 150

°C/°F

(2)

30

Delta T set-point maximum (referring to the temperature detected

by the needle probe)

r9 r7 r8

°C/°F

(2) 5

Delta T set-point for factory setting (referring to the temperature

detected by the needle probe)

r10 -199 199 °C/°F

(2) 10

work set-point during preheat (relative to the work set-point during

the first phase of the cooking cycle, i.e. “work set-point during the

first phase of the cooking cycle + r10”; referring to the temperature

detected by the environment probe); see also parameter r0

r11 0 500

°C/°F

(2)

50

work set-point during cooling (referring to the temperature detected

by the environment probe)

r12

0

240

min

240

duration of a power supply cut-off (3)

PARAM.

MIN.

MAX.

U.M.

DEF.

VARIOUS

c0 -1 120 s

10

duration of buzzer activation on conclusion of the cooking cycle

-1 = as long as it is silenced by hand

c1

0

1

- - -

0

activation of the buzzer (for 1 s) on conclusion of a cooking cycle

phase

c2 0 240 min 60

time that must pass without operations on the device (from

activation of the “Weekly programmed switch-on”) until this

switches off

c3 0 99

°C/°F

(2)

10

temperature over which the display of the temperature detected by

the environment probe is blocked (relative to the work set-point, i.e.

“work set-point + c3”)

0 = function

absent

c4 0 99

°C/°F

(2)

10

temperature above which the display of the temperature detected by

the environment probe is blocked (relative to the work set-point, i.e.

“work set-point - c4”)

0 = function

absent

PARAM.

MIN.

MAX.

U.M.

DEF.

FAN