Digital inputs for potential-free contact

Power supply:

none.

Protection:

none.

Digital inputs for high voltage contact

Power supply:

115... 230 VAC.

Protection:

none.

Analogue outputs:

1 0-10 V output for fan management (in this case, an external speed regulator

must be used).

Digital outputs:

8 outputs (electromechanical relays):

-

1 x 16 A res. output @ 250 VAC SPST type (K1) for temperature

regulation management

-

1 x 8 A res. output @ 250 VAC SPDT type (K2) for vent

management

-

1 x 8 A res. output @ 250 VAC SPST type (K3) for steam injection

management

-

1 x 8 A res. output @ 250 VAC type SPST (K4) or environment

light management.

-

1 x 8 A res. output @ 250 VAC type SPST (K5) for management of

the technical compartment fan

-

1 x 8 A res. output @ 250 VAC SPST type (K6) for management of

left fan rotation or fan enabling

-

1 x 8 A res. output @ 250 VAC SPST type (K7) for management of

right fan rotation or fan left/right rotation

-

1 x 16 A res. output @ 250 VAC SPDT type (K8) for fan speed or

steam reduction management.

The maximum current allowed on the loads is 10 A.

Displays:

3.5 inch, 16 colour TFT touch-screen graphical display with

320 x 240 pixel resolution.

Type 1 or Type 2 actions:

Type 1.

Complementary features of Type 1 or Type 2

actions:

C.

Communication port:

2 ports:

-

1x RS-485 MODBUS port

-

1 x USB port.

Signal buzzer and alarm:

incorporated.