Digital inputs for potential-free contact
Power supply:
none.
Protection:
none.
Digital inputs for high voltage contact
Power supply:
115... 230 VAC.
Protection:
none.
Analogue outputs:
1 0-10 V output for fan management (in this case, an external speed regulator
must be used).
Digital outputs:
8 outputs (electromechanical relays):
-
1 x 16 A res. output @ 250 VAC SPST type (K1) for temperature
regulation management
-
1 x 8 A res. output @ 250 VAC SPDT type (K2) for vent
management
-
1 x 8 A res. output @ 250 VAC SPST type (K3) for steam injection
management
-
1 x 8 A res. output @ 250 VAC type SPST (K4) or environment
light management.
-
1 x 8 A res. output @ 250 VAC type SPST (K5) for management of
the technical compartment fan
-
1 x 8 A res. output @ 250 VAC SPST type (K6) for management of
left fan rotation or fan enabling
-
1 x 8 A res. output @ 250 VAC SPST type (K7) for management of
right fan rotation or fan left/right rotation
-
1 x 16 A res. output @ 250 VAC SPDT type (K8) for fan speed or
steam reduction management.
The maximum current allowed on the loads is 10 A.
Displays:
3.5 inch, 16 colour TFT touch-screen graphical display with
320 x 240 pixel resolution.
Type 1 or Type 2 actions:
Type 1.
Complementary features of Type 1 or Type 2
actions:
C.
Communication port:
2 ports:
-
1x RS-485 MODBUS port
-
1 x USB port.
Signal buzzer and alarm:
incorporated.