Futaba SBD-1 User Manual

Instruction manual

Advertising
background image

CAUTION



Do not connect any device (gyro, battery,

etc.) other than servos to the servo

connector of the SBD-1. There is the danger of

erroneous operation or damage.



Do not connect an S.BUS connector

of the SBD-1 to other than an S.BUS

servo connection port. There is the danger of

erroneous operation or damage.

WARNNG



Always use in the state in which the

SBD-1 is firmly attached to the fuselage

of the airplane or helicopter. There is the danger

of loss of control and crashing if the connector is

disconncted by vibration and shock.

Futaba Corp. will not be responsible for

damage caused by combination with other

than Futaba Genuine parts.

S.BUS Decoder

INSTRUCTION MANUAL

Before using your new SBD-1, please read this manual

thoroughly and use the system properly and safely.
After reading this manual, store it in a safe place.

•Channel setting by SBC-1

1

Connect the

S.BUS connector of the SBD-1

to the

S.BUS servo connection port of the

SBC-1.

2

C o n n e c t t h e b a t t e r y t o t h e b a t t e r y

connection port of the

SBC-1.

* Status display LED blinks slowly. (About 1 sec/time)

3

Quickly press and release the

SBC-1 setting

switch and select the servo connection port

at which the channel is to be set.

* Each time the switch is pressed, the set servo

connection port and the number of times the LED

blinks change.

SBC-1

SBD-1 servo con-

nector selection

Setting switch

operation

LED display

W h e n p o w e r

turned on

1 s h o r t b l i n k

each second

Connector (

SX1)

selected.

Switch pressed

a n d r e l e a s e d

quickly

2 s h o r t bl i n k s

each second

Connector (

SX2)

selected.

Switch pressed

a n d r e l e a s e d

quickly

3 s h o r t bl i n k s

each second

Connector (

SX3)

selected.

*

(Channel confirmation)

When the operation position of the channel selector

switch and the channel set at the connector during

the SBD-1 servo connector selection coincide, the

LED changes to a steady light.

4

Set the

SBC-1 channel selector switch to

the channel you want to set.

5

Hold down the setting switch (about 1

second).

©Copyright 2010. No part of this manual may be reproduced in any form without prior permission. The contents of this

manual are subject to change without prior notice. While this manual has been carefully written, there may be inadvertent

errors or omissions. Please contact our service center if you feel that any corrections or clarifications should be made.

FUTABA CORPORATION Phone: +81 475 32 6982, Facsimile: +81 475 32 6983

1080 Yabutsuka, Chosei-mura, Chosei-gun, Chiba 299-4395, Japan

1M23N23401

©FUTABA CORPORATION 2010, 2 (1)

Meaning of Special Markings

Pay special attention to safety where indicated by the following marks:

DANGER

Procedures which may lead to dangerous conditions and

cause death/serious injury if not carried out properly.

WARNING

Procedures which may lead to a dangerous condition or

cause death or serious injury to the user if not carried out

properly, or procedures where the probability of superficial

injury or physical damage is high.

CAUTION

Procedures where the possibility of serious injury to the user

is small, but there is a danger of injury, or physical damage,

if not carried out properly.



= Prohibited



= Mandatory

Usage Precautions

Name of Each Part and Accessories

Channel Setting

Usage Method

•Connection

1

Connect the

S.BUS connector of the SBD-1

to the receiver

S.BUS connection port or

S.BUS hub.

2

Connect a conventional servo or an

S.BUS

servo to the servo connector of the

SBD-1.

* When an S.BUS servo was connected, that servo

will operate as a conventional servo. However,

it operates on the channel set at the servo

connector of the SBD-1 instead of the channel set

at the servo itself.

Thank you for purchasing an

SBD-1, S.BUS

*1

decoder. The

SBD-1 is a converter for using

conventional servos (other than

S.BUS servo

*2

) with

the

S.BUS system.

There are five types of

SBD-1 available as follows.

Type

Total Length

S.BUS Decoder

SBD-1

200

200mm (8in.)

400

400mm (16in.)

600

600mm (24in.)

1100

1,100mm (43in.)

1600

1,600mm (63in.)

Before installing the

SBD-1 to the fuselage, set

each channel at each servo connector (

SX1~3).

Use the

SBC-1 S.BUS channel changer or CIU-2

USB adapter (

PC-Link software for setting) to set

the channel.

* S.BUS decoder channel setting is impossible with

the S.BUS receiver R6108SB.

* PC-Link software can be downloaded from the

home page of your region's Futaba importer.

Conventional servo

(or S.BUS servo)

to the receiver

S.BUS con-

nection port or

S.BUS hub

SX1

SX2

SX3

SBD-1

Servo connector

(Upper)

SX1

(Middle)

SX2

(Lower)

SX3

S.BUS connector

[SBD-1 Ratings]

• Dimensions:

41.8x12.3x8.4mm

(1.65x0.48x0.33in.)

(excluding protruding)

• Weight:

6.9/10.8/14.7/24.5/34.3g

(0.24/0.38/0.52/0.86/1.21oz.)

• Power requirement:

Ni-Cd, Ni-MH 4 to 5 cells

equivalent battery (Futaba)

• O p e r a t i n g t e m p e r a t u r e

range: -10 to +45°

* During channel setting, the LED blinks quickly

(about 5 times/sec). When the LED changes to a

steady light, channel setting is complete.

6

To s e t t h e c h a n n e l o f o t h e r s e r vo

connection por ts, quickly press and

release the setting switch and repeat steps

4 and 5.

<Accessories>

Channel No. Label

• Put the channel No. label on the servo connector

for the identification of channel No..

Instruction manual (this manual)

*1

S.BUS: Serial communication system for Futaba R/C system

*2

Use the

S.BUS hub as the extension code used for the S.BUS servo. Also SBD-1 can be used.

Advertising