Futaba SBS-01T User Manual

Futaba Hardware

Advertising
background image

<表面>

<裏面>

Telemetry System

Telemetry System

●用途:

温度センサー

●測定範囲:

-20℃~200℃

●全長:

535mm●重量:

4.7g

●電圧:

DC3.7~

7.4V

温度センサー

MADE IN TAIWAN

Temperature Sensor

1M25A11701

4 513886 306273

00106836-1

SBS-01T-01

Temperature Sensor

Temperature Sensor

LED

to telemetry receiver

S.BUS2 Port

Temperature

detection part

Please take care to ensure that the

only portion of the temperature

sensor that touches the desired

surface (cylinder head, motor can,

etc.) is the sensing unit itself as

indicated in the image below.

To prevent damage, do not allow

the remaining parts of the SBS-01T

to touch the areas that will become

hot.

Green--Normal operation
Red--No signal reception

Green/Red--When setting
up the slot

Green/Red Alternate blink
--Unrecoverable error

Mounting Precautions

The SBS-01T may only be used with telemetry

enabled receivers that offer S.BUS 2 port(s).

Please refer to the manual(s) that accompanied

your transmitter and/or receiver for proper

connection methodology. Please note that the

proper default slot for this accessory is number

one. Information on how to change the slot

assignment is included in the transmitter's manual.

Receiver connection / Slot

setup

LED Indication

Thank you for purchasing Futaba's

SBS-01T Temperature Sensor.

This sensor, used in conjunction

with a telemetry enabled transmitter/receiver, is used to indicate

the operating temperatures of the item to which it is attached.

To maximize your enjoyment, and to ensure proper sensing,

please read through this manual thoroughly. We also encourage

you to retain the manual for future reference should the need

arise.

The maximum operating temperature for the SBS-01T
is 200.

If used in applications that exceed the maximum operating

temperature there is the risk of damaging the unit.

Ensure that the unit is mounted in an area that will
eliminate exposure to fuel, water and vibration.

As with any electronic components, proper precautions are urged to prolong the

life and increase the performance of the SBS-01T.

To ensure that the SBS-01T is functioning as desired,
please test accordingly.

Do not fly until inspection is complete.

Allow a slight amount of slack in the SBS-01T cables
and fasten them at a suitable location to prevent any
damage from vibration during flight.

Futaba Service Center

3002 N Apollo Drive Suite 1, Champaign, IL 61822

U.S.A.

TEL (217)398-8970 or E-mail: [email protected]

(Support)

WARNING

WARNING

To utilize the SBS-01T temperature sensor, connect it
to the S.BUS2 port of the Futaba telemetry enabled
receivers.

The SBS-01T will not function properly if connected to an

S.BUS port or other channel ports.

Do not use the SBS-01T with anything other than an
R/C model.

Ensure that the unit is connected properly to the
receiver. Failure to do so could result in damage to
the sensor.
To prevent any burns, always mount the SBS-01T to
the engine after it has completely cooled.

Advertising