Changing the Operating Voltage

The tablet may be operated at 100-125 Volts AC or at 200-250 Volts AC. If the operating
voltage of the table is not the same as the operating voltage in your locale, follow the steps
below to change it.

1. Disconnect the tablet from the line cord.

2. Insert a small flat blade screwdriver into the notch at the left of the fuse block cover.

Gently pull the left end of the fuse block cover up and remove the fuse holder.

Set aside cover/fuse block assembly for now.

3. Pull the voltage selector card straight out of its housing at the right, using the

indicator pin as a handle. (Needle nose pliers are a help here.)

4. Orient the selector card so that the desired voltage label is right side up. Pull the

indicator pin down to free it from the detent, turn it ¼ turn to the right and then
slide it up and to the right as far as possible.

Turn the pin another ¼ turn to make it point up or away from the voltage label and
then slide the pin down into the detent at the top of the card.