GTCO DrawingSlate I & II Commands User Manual

Page 5

Advertising
background image

23 Format (2G) from 0 to 1 FH (0 to 31) Only If Pressure Pen Data is Enabled
7 6

5

4

3

2

1

0

1 1 P4 P3 P2 P1 P0 X15 X14 PRESSURE 0 TO 31
2 0 X13 X12 X11 X10 X9 X8

X7

3 0 X6

X5

X4

X3

X2 X1

X0

4 0 0

PR X17 X16 Y16 Y15 Y14 PR 0 = IN PROX 1 = OUT OF PROX

5 0 Y13 Y12 Y11 Y10 Y9 Y8

Y7

6 0 Y6

Y5

Y4

Y3

Y2 Y1

Y0


28 Format (2B) Also 25 (Cursor Coding Different between 25 and 28)
7 6 5

4

3

2

1

0

1 0 1 C3 C2 C1 C0 C4 PR PR 0 = IN PROX 1 = OUT OF PROX
2 0 0 X5

X4

X3 X2 X1 X0 On format 28 no c4 bit

3 0 0 X11 X10 X9 X8 X7 X6
4 0 0 Y5

Y4

Y3 Y2 Y1 Y0

5 0 0 Y11 Y10 Y9 Y8 Y7 Y6

30 Format
7 6

5

4

3

2

1

0

1 1 PR T0

X14* Y14* C2 C1 C0 PR 0 = IN PROX 1 = OUT OF PROX

2 0 X6

X5

X4

X3

X2 X1 X0

3 0 X13 X12 X11 X10 X9 X8 X7
4 0 Y6

Y5

Y4

Y3

Y2 Y1 Y0

5 0 Y13 Y12 Y11 Y10 Y9 Y8 Y7
6 0 p6 p5 p4

p3

p2 p1 p0 If pressure is enabled 0 to 127


30 Format DELTA
7 6

5

4

3

2

1

0

1 1 PR T0 X14* Y14* C2 C1 C0 PR 0 = IN PROX 1 = OUT OF PROX
2 0 X6 X5 X4

X3

X2 X1 X0

3 0 Y6 Y5 Y4

Y3

Y2 Y1 Y0


NOTE:
Can only get to DELTA format using mm commands. X14* and Y14* are set high (1)
for + and low (0) for X14, Y14 not.


Advertising