Figure 3-10
Relay Specification
Model:
JRC-27F
Material of 
the contact 
Silver
Rated switch capacity
30VDC 2A, 125VAC 1A
Maximum switch power
125VA 160W
Maximum switch voltage
250VAC, 220VDC
Rating
(
resistance
load)
Maximum switch currency 1A 
between contacts with 
same polarity 
1000VAC 1minute 50/60Hz
between contacts with 
different polarity 
1000VAC 1minute 50/60Hz
Insulation
between contact and 
winding 
1000VAC 1minute 50/60Hz
Surge 
voltage 
between contacts with 
same polarity 
1500V (10×160us)
Length of 
open time 
3ms max
Length of 
close time 
3ms max
Mechanical
50×106 times (3Hz)
Longevity
Electrical
200×103 times (0.5Hz)
Temperature -40℃ ~+70℃
3.8 RS485
Please follow the steps listed below for PTZ cable connection. See Figure 3-11. 
z
Connect speed dome 485 cable to the ATM 485 port.