53
Please refer to the following sheet for detailed information.
Parameter Function
Event 
Type 
There are three types: Motion detection/video loss/Camera Masking.
Channel
Select channel name from the dropdown list.
Enable
You need to draw a circle to enable motion detection function.
Sensitivity There are six levels. The sixth level has the highest sensitivity.
Region
Region: If you select motion detection type, you can click this button 
to set motion detection zone. The interface is shown as Figure 
5-39. There are PAL 22X18/NTSC 22X15 zones. Right click mouse 
you can go to full-screen display mode. Do remember clicking OK 
button to save your motion detection zone setup. 
Period
Motion detection function becomes activated in the specified 
periods. 
There are six periods in one day. Please draw a circle to enable 
corresponding period. 
Select date. If you do not select, current setup applies to today only. 
You can select all week column to apply to the whole week. 
Click OK button, system goes back to motion detection interface; 
please click save button to exit. 
Anti-dither System only memorizes one event during the anti-dither period. The
value ranges from 0s to 15s.
Alarm 
latch 
System can delay the alarm output for specified time after alarm ended. 
The default value is 10s 
Alarm 
upload 
System can upload the alarm signal to the centre (Including alarm 
centre. 
Record 
channel 
System auto activates motion detection channel (multiple choices) to 
record once alarm occurs (working with motion detection function). 
Please note you need to set motion detection record period and set 
current period as auto record. 
Record 
latch 
System can delay the record for specified time after alarm ended. The 
value ranges from 10s to 300s. 
If you enabled this function, System can send out email to alert you 
when alarm occurs and ends. 
Tour
Display the selected video in local monitor window.
Tour interval and tour mode are set in NVS local menu.
PTZ 
Activation 
Here you can set PTZ movement when alarm occurs. Such as go to 
preset x when there is an alarm. 
Capture
You need to input capture channel number so that system can backup 
motion detection snapshot file. 
Copy
It is a shortcut menu button. You can copy current channel setup to 
one or more (all) channels. 
Save
You can click save button after you complete setup for one channel, 
or you can complete the whole setups and then click save button. 
Refresh
Click this button to get device latest configuration information.