Interlogix NS3502-8P-2S User Manual User Manual

Page 328

Advertising
background image

IFS NS3502-8P-2S User Manual

328

The page includes the following fields:

Object

Description

System PoE Admin

Mode

Allows user enable or disable PoE function. It will cause all of PoE
ports supply or not supply power.

Power

Management
Mode

There are five modes for configuring how the ports/PDs may
reserve power and when to shut down ports.
Classification mode: System reserves PoE power to PD according
to PoE class level.
Allocation mode: allows user to assign PoE power to per port.
Consumption mode
: System offers PoE power according to PD
real power consumption.
Priority mode: System offers PoE power according to per port
priority setting when power consumption has been over total
power budget.
The default PoE management mode is “Consumption mode”.

Power Supply

Budget [W]

Set limit value of the total PoE port provided power to the PDs.
For NS3502-8P-2S, the available max. Value is 150.

Temperature

Threshold

Allows setting over temperature protection threshold value. It
system temperature was over it then system lower total PoE
power budget automatically.

PoE Usage

Threshold

Allows setting how much PoE power budget could be limited.


Buttons

: Click to save changes.

: Click to undo any changes made locally and revert to previously saved values.

For NS3502-8P-2S, the total PoE power reservation from Port-1~8 is up to

150W


PD Classifications

A PD may be classified by the PSE based on the classification information provided by the PD. The
intent of PD classification is to provide information about the maximum power required by the PD
during operation. Class 0 is the default for PDs. However, to improve power management at the PSE,
the PD may opt to provide a signature for Class 1 to 4.

Advertising