Fuel conversion procedure – Vermont Casting NV360 User Manual

Page 17

Advertising
background image

17

Vermont Castings Majestic Products NV360/580 Series

20003565

Fuel Conversion Procedure

Honeywell Valve Only

This conversion is for the NV360/580 equipped with a
Honeywell valve only. Before proceeding, turn control
knob on valve to “OFF” and turn gas supply OFF. Turn
OFF any electricity that may be going to the appliance.

CAUTION: Logs may be HOT! Allow to cool before
proceeding.

1. Open bottom grille to gain access to valve. Remove

glass door. (See "Window Frame Assembly Re-
moval", Page 10, Fig. 10)

2. Remove logs if previously installed.
3. Remove cap from Hi/Lo knob. This can be accom-

plished by lifting the plastic cap off the screw. (Fig.
21)

4. Remove the screw from center of Hi/Lo knob with

small screwdriver turning counterclockwise. (Fig. 21)

5. Insert conversion screw supplied in kit. Blue for

Natural Gas and Red for LP Gas.

6. Tighten screw, replace cap.
7. Remove manifold mounting screw from burner. (Fig.

22)

8. Remove burner orifice from manifold assembly using

3/8" wrench. (Fig. 23)

9. Install conversion orifices in place of orifices just

removed.

10. Remove both air shutters from burner pan by

removing shutter retaining screw then air shutter.
(Fig. 24)

Fuel conversion must be completed by qualified personnel

LO

HI

LO

HI

Hi-Lo Knob

Cap

Lift Open

Remove
Center Screw

CO100

Fig. 21 Removing center screw from Hi/Lo knob.

Manifold
Assembly

Orifice

Log Support

NV580 Pilot Location

CO101a

Burner Pan

NV360 Pilot Location

Manifold Mounting
Screw

Fig. 22 Removing manifold assembly.

CO102a

Rear Burner Orifice:
#53 (NV360)
#51 (NV580)

Front Burner Orifice:
#74 (NV360)
#65 (NV580)

Fig. 23 Remove burner orifice, replace with LP orifice.

Fig. 24 Remove air shutter from burner pan.

Shutter
Retaining
Screw

Burner Pan

Air Shutter

Front View

CO103

Shutter Retaining Screw

Slots Covered

Burner
Pan

One (1) Hole Closed

Holes Open

Natural Gas

Front View

Holes Open

Holes Open

Burner Pan
NV360

Burner Pan
NV580

Shuter
Retaining
Screw

Slots Open

Front View

Top View

CO110

Fig. 25 Install conversion air shutters.

11. Install air shutters supplied in kit on burner pan.

Replace shutter retaining screw. For conversion to
Natural Gas adjust new air shutters so slots are
covered. For conversion to Propane Gas, adjust new
air shutters so slots are open. NOTE: NV360 air
shutter has only one hole, closed. Secure shutter
retaining screws. (Fig. 25)

12. Re-install manifold to burner pan.

NOTE: It is not necessary to remove the pilot tube
for conversion.

Advertising