Optional accessories available, Fan kits – Vermont Casting NV360 User Manual

Page 22

Advertising
background image

22

Vermont Castings Majestic Products NV360/580 Series

20003565

Optional Accessories Available

Fan Kits

FK24 Fan Assembly

Fan specifications: 120 volt, 60 Hz .75 Amp.
This fan does not need regular maintenance, however,
periodic cleaning is required. Check the area under the
control door and in front of the fan and wipe or vacuum
at least once a month during the operating season.
Should this fan require servicing, the power supply
must be disconnected.

The FK-24 comes with the electrical cord attached.
1. Slide fan assembly from the left side into the fire-

place opening, line up mounting holes with screw
studs on back of fireplace and fasten with #10-24
hex nuts.

2. Install thermal sensor on bottom of firebox using

#10-24 hex nuts.

3. (Option A) - Place electronic fan speed control box

on bottom of fireplace base, lining up mounting holes
with screw studs. Fasten fan speed control box with
#10-24 hex nuts.
(Option B) - The speed control can be installed in
an electrical box at normal wall switch height for
convenient access.

4. The power supply may be connected in two (2)

ways:

FK12 Fan Assembly

1. Open lower louvre.
2. Install FK12 fan in back of unit between hearth

supports. (Fig. 29)

3. Secure fan on velcro strips.
4. Power to the fan can be supplied by plugging the

supply lead into a conveniently located wall socket
or by using a hard-wired EB1 connector box.

5. Be sure fan motor does not touch nearby metal.

Method A

Route the 6’ (1.8m) lead fitted to the unit to a con-
veniently located wall socket.

Method B

If the EB1 receptacle box (Pt. #ZA1200) was cor-
rectly connected when the unit was installed, the fan
lead can be directly plugged in to the EB-1 plug
socket.

5. Whether wiring directly to the fan junction box

(Option A) or into the EB1 (electrical receptacle box,
Option B) first ensure cable is secured using box
connector.

The fireplace, when installed must be electrically
connected and grounded in accordance with local
codes or, in the absence of local codes, with the
current CSA C22.1 Canadian Electrical Code or for
USA installations, follow local codes and the Na-
tional Electrical Code, ANSI/NFPA No. 70.

Hard (Direct) Wire Hook-Up

First connect ground wire to ground stud located on the
base of either box. Black wire from supply should
connect to the variable speed switch. Alternate speed
switch wire connects to temperature sensor. Alternate
lead from sensor connects to fan. Alternate fan lead
connects back to the white supply wire. (Fig. 31)

Any electrical re-wiring of this fan must
be completed by a qualified electrician.

Turn off all power before hook-up.

Cold Air
Box

Front of
Unit

Hearth Pan

Base Pan

FK12 Fan

Side View

FP1004

Fig. 29 FK12 Fan Kit placement.

HI

L O

O

FF

ON

O F F

P

IL

O

T

O

FF

E

A

PIL

OT

T

P

T

H

Electrical
Box

Heat
Sensor

Fan

Valve

Gas Line

Fan Speed
Switch

FP1026

Fig. 30 FK-24 fan placement.

Black

White
Ground

Speed Control

Temperature
Sensor

Fan

FP1025

Fig. 31 FK-24 fan wiring.

Advertising