Vermont Casting NV360 User Manual

Page 8

Advertising
background image

8

Vermont Castings Majestic Products NV360/580 Series

20003565

Attic Insulation

Firestop position when area above ceiling is an attic

Nails (4)

Firestop Spacer

Joist

Ceiling Installation

Firestop position when area above ceiling is NOT an attic

(Firestop/draftstop
appearances may
vary. Only one (1)
firestop required
per frame.)

FP384

Fig. 8 Firestop/draftstop positions.

Install the Venting System, Flashing

and Termination

NOTE: The NV360 uses a 6” B-vent system. The
NV580 uses an 8” B-vent system (refer to Accessories,
Page 25, for adapter).

Refer to venting installation instructions provided by the
B-vent manufacturer.

Refer to Page 4, Figure 1 to locate chimney centerline
dimension from a combustible back wall.

Minimum vertical chimney height - 12 feet
(3.65m) (measured from the bottom of the fire-
place)

Maximum vertical height - 40 feet (12m)

Minimum height with two elbows - 18 feet (4.6m)

Elbow requirements allow a maximum of two 90

°

elbows or four 45

°

elbows per installation. (Two

45

°

elbows = one 90

°

elbow.) Refer to the venting

chart for proper elbow offset runs.

For firestop positioning, refer to Figure 8. Only one (1)
firestop required per frame. NOTE: A firestop is not
required at the roof.

FP580

OUTSIDE

ELECTRICAL BOX

FRONT OF UNIT

INSIDE

FRONT OF UNIT

Fig. 7 EB-1 receptacle.

6. Connect the white wire of the power line to the

chrome screw of the socket assembly.

7. Connect the ground wire of the supply line to the

green screw of the socket assembly.

8. Refit the socket assembly back into the electrical

box and replace the cover plate. Secure the cable
with the clamp on the outside of the unit to prevent
strain on the connections.

9. The EB-1 electrical junction box is now ready to

supply power to the FK12 or FK24 fan kits if fitted.

Advertising