Hearth, Mantels, Clearance to combustibles – Vermont Casting NV360 User Manual

Page 5: Mantel chart

Advertising
background image

5

Vermont Castings Majestic Products NV360/580 Series

20003565

Hearth

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth.

O

N

M

L

K

J

F

G

H

I

Mantel
Leg

CFM164a

Fig. 2b Combustible mantel leg minimum installation.

Man-
tel
Leg

CFM170

Mantel

Mantel Leg from Side

Ref.

Leg Depth

Ref.

of Comb. Opening

F

10” (254mm)

K

11

¹⁄₂

” (292mm)

G

8” (203mm)

L

9

¹⁄₂

” (241mm)

H

6” (152mm)

M

7

¹⁄₂

” (191mm)

I

4” (101mm)

N

5

¹⁄₂

” (140mm)

J

2” (50mm)

O

3

¹⁄₂

” (89mm)

Cold climate installation recommendation:

When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be
insulated to conform to applicable
insulation codes.

Side of Combus-
tion Chamber

Black
Surround
Face

Mantels

\

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.

For the correct mounting height and widths refer to
Figures 2a, 2b and the Mantel Chart below.

The distances and reference points are not affected by
the fitting of a bay window front trim kit.

Noncombustible mantels and legs may be installed at
any height and width around the appliance.

When using paint or lacquer to finish the mantel,
such paint or lacquer must be heat resistant to
prevent discoloration.

Clearance to Combustibles

Appliances

Top .......................................... 0” (0mm)
Bottom ..................................... 0” (0mm)
Side ......................................... 0” (0mm)
Back ......................................... 0” (0mm)
Perpendicular Sidewall ............ 0” (0mm)
Top of unit to ceiling ................ 36” (914mm)
Front of unit to combustibles ... 36” (914mm)

Venting

B-Vent ...................................... 1” (25mm)

Side View

Fig. 2a Combustible mantel minimum installation.

CFM146

Mantel Chart

Mantel Shelf

Mantel from Top

Ref.

or Breast Plate

Ref. of Comb. Chamber

V

10” (254mm)

A

19” (483mm)

W

8” (203mm)

B

17” (432mm)

X

6” (152mm)

C

15” (381mm)

Y

4” (101mm)

D

13” (330mm)

Z

2” (50mm)

E

11” (279mm)

A

B

C

D

E

V

W

X

Y

Z

Fireplace

Louvre Assembly Top

Top of Comb. Chamber

Bottom of Door Trim

Advertising