21

COMPRESSOR

ACCUMULATOR

OUTDOOR COIL

INDOOR COIL

LCS

LEGEND

HPS – High Pressure Switch

LCS – Loss of Charge Switch

Accurater

®

Metering De vice

Arrow indicates direction of flo

w

TXV in Metering

Position

Bypass

Position

HP S

C03011

Fig. 20 -- Typical Heat Pump Operation, Cooling Mode

COMPRESSOR

ACCUMULATOR

OUTDOOR COIL

INDOOR COIL

LCS

LEGEND

HPS – High Pressure Switch

LCS – Loss of Charge Switch

Accurater

®

Metering De vice

Arrow indicates direction of flo

w

TXV in Bypass

Position

Metering

Position

HP S

C03012

Fig. 21 -- Typical Heat Pump Operation, Heating Mode