MIDI Diagnostics Mode

The Pro-2000 has a built-in MIDI analyser function. This feature allows you to see what types of MIDI

messages are being transmitted by your master keyboard/sequencer, making the PRO 2000 a useful

diagnostic tool, which can help you when you have a problem with your MIDI set-up.

To enter analyser mode, you must power on the PRO 2000 whilst holding the SELECT button. The

display will then show ‘CHANnel’, ‘NOTE#’ and ‘VELOCity’, and will display the relevant data, below
the heading. Using the INC, DEC, SELECT and ENTER buttons, different types of MIDI messages received

may be displayed as follows:-

SELECT

Short press

CLock,STATUS and SYSEX data received for checking MIDI clock.

DEC

Short press

CHANnel,NOTE# and VELOCity as above, note information.

INC

Short press

CHANnel,CONTroller# and VALUE displays controller information.

Long press

CONTROLLER IDENTity - displays the name of the rec’d controller.

ENTER

Short press

CHANnel,PROG# and BANK# - displays program change as rec’d.

Although pitchbend and after-touch are not strictly controllers, they will be identified and treated as if
they are controllers for the purposes of the analyser mode.

MIDI Controller Numbers

Controller Number

Control Function

Decimal Hex

0

00H

Bank switch MSB

1

01H

Modulation wheel/lever

2

02H

Breath controller

3

03H

Undefined

4

04H

Foot controller

5

05H

Portamento time

6

06H

Data entry MSB

7

07H

Main volume

8

08H

Balance

9

09H

Undefined

10

0AH

Pan

11

0BH

Expression controller

12-15

0C-0FH

Undefined

16-19

10-13H

General purpose controllers (1-4)

20-31

14-1FH

Undefined

32-63

20-3FH

LSB for values 0-31

64

40H

Damper pedal (sustain)

65

41H

Portamento

66

42H

Sostenuto

67

43H

Soft pedal

68

44H

Undefined

69

45H

Hold 2

70-79

46-4FH

Undefined

80-83

50-53H

General purpose controllers (5-8)

84-90

54-5AH

Undefined

91

5BH

External effects depth

92

5CH

Tremolo depth

93

5DH

Chorus depth

94

5EH

Celeste (detune) depth

95

5FH

Phaser depth

96

60H

Data increment

97

61H

Data decrement

98

62H

Non-registered parameter number LSB

99

63H

Non-registered parameter number MSB

100

64H

Registered parameter number LSB

101

65H

Registered parameter number MSB

102-119

66-77H

Undefined

120-127

78-7FH

Reserved for channel mode messages