CV x LFO DEPTH CONTROL

(pb, vel, aft, controllers 0-119, default: #1 mod wheel).

- assigns which MIDI controller will control the LFO depth of modulation of the CV output.

CV x LFO DEPTH AMOUNT

(for controller maximum 0-127, default:65).

- allows you to set the maximum LFO depth for the CV out

CV x LFO ASSIGN Use LFO number

(1 to 2, default: A=1, B=2)

- lets you assign which of the two inbuilt LFOs will modulate the CV outputs.

CV x Gate Select

(default: 5v pull-up)

- you can select the following type outputs for the Gate output;

S-trig no pull-up

This would probably be used for Moogs & Korgs.

S-trig 5v pull-up
S-trig 15v pull-up

This would probably be used on the Yamaha CS range of synths instead of the Gate output.

Gate V-Trig 5v pull-up
Gate V-Trig 15v pull-up

These are the standard gates and should be used to run most synths including Roland,Arp, SCI.

CV x Fine Tune

( -127 to +127 default 0)

-

Fine tunes the mono-synth.

CV x Scale

( -127 to +127 default 0)

- This is used to tune in the octave scaling of your analogue synth. Will only need adjusting if your
synth sounds out of tune as you play further up the keyboard (see `Tuning in Your Analogue Synth`). -
Check whether CV select has been set correctly (see below).

CV x CV/HZ Select

( volt/oct or hz/v default:volt/oct scaling)

-

This is used to select the scaling method, most synths will use the VOLT/OCTAVE, although some

Korgs and Yamaha synths will require the HZ/V selection, see your synths user manual to confirm which