Network Communications
•

an RS-232 serial port that automatically configures itself to communicate directly
to a PC or communicate to a PC via modem

•

an RS-485 network communication port capable of linking up to 128 controllers
on a single network up to 4,000 feet long (or up to 16,000 feet under specific
conditions – refer to Appendix 3: PXL-250 Network Wiring Application Note)

Automatic Network Configuration
•

automatic configuration of earth ground to one point to support network
communications

Access Control Database Capacity
•

transaction buffers capable of storing up to 3,640 events per controller

•

a database capacity of up to 10,920 unique cardholders per controller, OR

•

with optional RAM expansion, up to 65,535 unique cardholders per controller

Support for the Following Reader Technologies
•

Keri Systems Proximity

•

Wiegand Compatible (26-bit)

– Bar Code
– Biometrics
– Keypad
– Magnetic Stripe
– Other Proximity

NOTE: Wiegand readers must send data according to the Security Industry
Association's Wiegand Reader Interface Standard (document number AC-01D-96).
Keri Systems, Inc. cannot guarantee the performance or reliability of Wiegand readers
that do not meet these guidelines.

The optional LCD-1 Alpha/Numeric Plug-In Display adds the following feature.
•

access to built-in system diagnostics to aid in troubleshooting (highly
recommended)