0 cable requirements, 1 rs-232 serial cable, 2 rs-485 network cable – Keri Systems SB-293 User Manual

Page 19: 3 input power, 4 earth ground, Cable requirements

Advertising
background image

Keri Systems, Inc.

Technical Reference Manual – PXL-250 and SB-293

Revision 5.5

P/N: 01836-004

Page 19

4.0

Cable Requirements

4.1

RS-232 Serial Cable

•

four conductor, shielded, stranded, AWG 24 wire (such as Belden 9534 or a larger
gauge)

•

50 feet maximum length (per RS-232 industry specification)

4.2

RS-485 Network Cable

•

two conductor, shielded, twisted pair, stranded, AWG 24 wire (such as Belden
9501 or a larger gauge)

•

16,000 feet total network length

•

refer to the Network Wiring Application Note (P/N 01824-002) for specific
network wiring information

4.3

Input Power

•

two conductor, stranded, AWG 18 wire (such as Belden 8461 or a larger gauge)

•

200 feet maximum cable length for systems using an SB-293 with two readers

NOTE: On long power cable runs, the resistance in the cable itself causes a drop in
voltage at the end of the run. Be sure that your power supply does provide 12 VDC at
the end of the cable run.

4.4

Earth Ground

•

single conductor, AWG 18 wire (or a larger gauge)

1

1. Ground wire is green with or without yellow tracer.

Advertising