Keri Systems SB-293 User Manual

Page 43

Advertising
background image

Keri Systems, Inc.

Technical Reference Manual – PXL-250 and SB-293

Revision 5.5

P/N: 01836-004

Page 43

NOTE: All Keri Systems proximity readers can use between 5 and 12 VDC power
while most Wiegand compatible readers use 5 VDC power. Check your reader's
requirements and verify jumper JP4 is set correctly per the Jumper Settings
instructions on page 28. Early r
evisions of the surface mount PXL-250W mislabeled
the JP4 jumper as JP5. All instructions for the JP4 jumper apply to the jumper
labeled as JP5 (see Figure 9-1 on page 39 for the location of the jumper).

a. Refer to the Wiegand compatible reader’s documentation
for the color of this wire.

Table 4: Single-Line LED Wiegand Compatible

Reader Connections

TB-5/TB-6

Description

Wire Color

Pin 1

Data 0

GREEN

Pin 2

Beeper

refer to reader

a

a. Refer to the Wiegand compatible reader’s

documentation for the color of this wire.

Pin 3

Reader Power

RED

Pin 4

Reader Ground

BLACK

Pin 5

n/a

n/a

Pin 6

Single LED Line refer to reader

a

Pin 7

Data 1

WHITE

Table 5: Dual-Line LED Wiegand Compatible

Reader Connections

TB-5/TB-6

Description

Wire Color

Pin 1

Data 0

GREEN

Pin 2

Beeper

refer to reader

a

Pin 3

Reader Power

RED

Pin 4

Reader Ground

BLACK

Pin 5

Green LED

refer to reader

a

Pin 6

Red LED

refer to reader

a

Pin 7

Data 1

WHITE