3.4

Current Draw

maximum current draw 270 mA for a controller plus reader current draw (refer to
Table 1 for Reader current draw)

120 mA max for a PXL-250 Controller

150 mA max for an SB-293 Satellite Board

NOTE: If an electronic locking device (such as a magnetic lock, a door strike, or
similar device) is to be driven by the same power supply as the PXL-250 controller,
please ensure the power supply provides enough current to drive every device
connected to that supply plus an adequate safety margin. AC power cannot be used.

3.5

Controller Memory Retention

5 year lithium battery back up to support controller RAM and real-time clock

3.6

Output Relay Contact Rating

1 Amp @ 24 VDC

3.7

Input Device Configuration

Door Sense

normally closed

Request to Exit

normally open

Global Unlock

normally open, or

Auxiliary RTE A-Door

normally open

Table 1: Proximity Reader Current Draw

Reader Type

MS-3000

MS-4000

MS-5000

MS-7000

MS-9000

Current

Draw

50 mA

50 mA

100 mA

200 mA

200 mA