LAARS IGI-180C-5(N,X) - Service Manual User Manual

Page 17

Advertising
background image

IV - SAFETY DEVICE FUNCTION

Flame Failure

Situated to the right of the burner in the front of the combustion chamber, the flame rod monitors the

combustion process. This sensor monitors the flame intensity, while the PCB compares this signal to

the feed back signal from the combustion fan motor, water flow control, and gas flow through the POV

valve. If any one of the feedback signals are incorrect, the unit will shut off, preventing discharge of

gas to the burner.

Over Heat Protection Device

Also referred to as an Over Heat Switch. This device is fitted to a bend section at the inlet to the heat

exchanger. If the flame remains on to the burner after the tap is closed and the water temperature

inside the heat exchanger reaches 194 ° F, a 12 volt DC bi-metal cut-off switch will shut off the gas

supply to the solenoids.

No Water

Should the incoming water flow become restricted or stop, the water flow sensor will cease to send a

magnetic pulse signal to the PCB, in turn preventing gas to flow into the combustion chamber. If you

have restricted flow, first check to ensure the inline water filter is not clogged.

Thermal Fuse (Non-Resettable)

Wrapped around the entire surface of the heat exchanger you will find a thermal fuse. This device

activates in the event of excessive heat exchanger temperatures, or the temperature outside the heat

exchanger reaches 264 °F. If the thermal fuse melts, it breaks an electronic circuit which in turn shuts

off the power supply to the gas solenoids, deactivating the unit.

Combustion Fan Revolution Check

The combustion fan rpm’s are continually monitored by a magnetic pulse generator connected to the

PCB. If the fan revolutions deviate from the speed required for complete combustion, a signal is sent

to the PCB and the revolutions adjust accordingly. (If not the unit deactivates)

Automatic Frost Protection

When the temperature inside the appliance drops below 37°F , the frost sensing device inside the

appliance activates the anti-frost heaters to prevent the water inside the unit from freezing. The anti-

frost heaters remain ON until the temperature inside the appliance rises to 57°F. There are four (16)

watt anti-frost heaters located at various points throughout the main water flow area of the appliance.

The unit also incorporates the ability to fire for (3) seconds in the event the anti-frost heaters can not

keep the water temperature from dropping below 37°F. This unique feature will heat the water in the

lines inside the appliance back up to 57°F. Both of the above features function as long as the unit

has power and gas. There is an optional freeze protection system that can be added to the unit’s

piping. Refer to the auto drain down diagram in the product installation instructions for instructions

on how to install the optional freeze protection in the event of a power failure.

17

Advertising
This manual is related to the following products: