IGI – 7. Removal of Transformer:

CAUTION

120 volt potential exposure. Isolate the appliance and

reconfirm power has been disconnected using a multi-

meter.

a.

Remove the combustion fan motor assembly

as described in IGI - 5 a,b.

b.

Remove the two (2) Phillips screws to release

the transformer.

c.

Disconnect wiring harness connectors to

transformer and pull out towards you.

IGI – 8. Removal of Burner Manifold and the Burner:

CAUTION

120 volt potential exposure. Isolate the appliance and

reconfirm power has been disconnected using a multi-

meter.

a.

To remove the burner manifold, remove (6)

Phillip screws around the burner plate as

shown in the upper right picture.

b.

Remove the (3) Phillip screws at the gas valve

assembly.

c.

Grip the burner manifold and remove it from

the unit.

d.

To remove the burner assembly remove

(8) Phillip screws around the sight glass

panel. Remove this panel.

e.

Locate the (2) Phillip screws inside the

burner chamber that hold the burner

assembly in place. Remove these two

screws, grip the burner assembly and

slide it out of the combustion housing.

f.

If you need to remove each burner from

this housing remove the (2) Phillip screws

on each side of the burner, as shown

below.