Unable to adjust hot water temperature

1) Is the water temperature thermistor operating normally?

2) Is the change over solenoid (SV1) normal?

43

a.

# Disconnect the connector B5, and measure the

resistance between the white wires, see below

for resistance readings.

Thermistor resistance valves:

59 ºF = 11.4 ~ 14 K Ω

86 ºF = 6.4 ~ 7.8 K Ω

113 ºF = 3.6 ~ 4.5 K Ω

140 ºF = 2.2 ~ 2.7 K Ω

221 ºF = 0.6 ~ 0.8 Ω

Normal: Proceed to check item 2 below.

Faulty: Replace the water temperature

thermistor.

(Service Procedure IGI-6, page 50)

a.

# Disconnect the changeover solenoid (SV1)

connector, and measure resistance at the

solenoid terminals.

Normal: 1.7 ~ 2.1 K Ω
If normal, proceed to b.
Faulty: Replace the gas valve.

(Service Procedure IGI-9, page 52)

b.

Measure the voltage at the changeover solenoid

(SV1) yellow ~ black wires.
Normal: 80 ~ 100 VDC
If normal, proceed to check item 3, on next
page.

Faulty: Replace the PCB unit.

(Service Procedure IGI-2, page 49)

VI - TROUBLESHOOTING

(cont.)

BEFORE CARRYING OUT CHECKS MARKED WITH A # SIGN, DISCONNECT THE POWER SUPPLY.