LAARS IGI-180C-5(N,X) - Service Manual User Manual

Page 50

Advertising
background image

b.

Remove the four (4) Phillips screws that secure

the water inlet filter housing to the unit. See

picture below for location of screws. Once

screws are removed reach into the unit and

pull up and out on the flow control assembly

to remove it from the appliance. Inspect o-ring

for damage.

c.

Disconnect wiring harness from assembly and

remove the water flow control assembly from

the unit.

IGI – 4. Removal of Ignition Module:

CAUTION

120 volt potential exposure. Isolate the appliance and

reconfirm power has been disconnected using a multi-

meter.

a.

Remove one (1) Phillips screw that secures the

sparker module to the unit casing.

b.

Disconnect high tension lead and connector.

IGI – 5. Removal of the Combustion Fan:

CAUTION

120 volt potential exposure. Isolate the appliance and

reconfirm power has been disconnected using a multi-

meter.

a.

Disconnect wiring harness from fan motor.

b.

Remove the (2) Phillips screws that secure the

combustion fan motor to the fan housing. Pull

the fan motor assembly towards yourself to

remove it.

IGI – 6. Removal of the Water Temperature

Thermistor:

CAUTION

120 volt potential exposure. Isolate the appliance and

reconfirm power has been disconnected using a multi-

meter.

a.

Remove the two (2) Phillips screws that secure

the thermistor in place to remove the water

outlet temperature thermistor.

50