I - GENERAL INFORMATION

This tankless water heater is a high output, high efficiency appliance, which heats the water

continuously as hot water is being drawn for use. Unlike tank type storage water heaters, this water

heater does not store hot water. The burner operates whenever there is a demand for hot water and

is off when the hot water flow stops. Hot water is continuously supplied for any length of time

required as long as the specified flow rates are not exceeded. There is no need to set the

temperature higher than required for sufficient capacity. This water heater has sufficient capacity to

supply several hot water faucets simultaneously. The hot water flow capability will be dependent

upon the temperature of the outlet water selected. Operational feature of this water heater include:

• The burners ignite by direct spark ignition within 3 seconds of detecting minimum

operational water flow. There is no standing pilot.

• A variable speed combustion air blower forces the combustion air supply into the burner

compartment.

• Direct vent design uses only outside air for combustion. The venting system is a coaxial

design requiring a single 5 1/4" (13.3 cm) hole through the outside wall or roof. Vent pipe

fittings have internal gaskets for a tight seal to prevent leakage of flue products and

combustion air.

• The burner flame is continuously monitored and modulated to match the heating

requirements of the water flow. Temperature and flow sensors continually monitor the

water flow and outlet water temperature and adjust the burner and combustion air blower

to maintain temperature.

• The Indoor Direct Vent model series have a digital temperature control integrally mounted

to the front panel of the water heater. The outlet water temperature is adjustable from

96-160°F for residential models or 96-180˚F for commercial models. The front panel

temperature control also displays fault codes if the water heater malfunctions to assist with

servicing the water heater. No installation is required for the main temperature control.

• In addition to the main temperature controller, up to two optional bathroom temperature

controls are available on the residential models for setting the water temperature in the

bathroom fixtures up to 120°F.

• The heat exchanger coil is provided with anti-freeze heaters for protection in cold climate

conditions to ambient temperatures as low as -30°F (-34°C). Drain solenoids should be

installed to drain the water heater in the event of a power failure.

(See installation instructions)

Tools Required for Troubleshooting

Multifunction Digital Test meter with needle point test leads.

Long reach (12") Magnetic Phillips screw driver (#2 Tip)

3/16 Allen wrench

Small (pocket size) blade screw driver

Monometer or Magnehelic inches water column gage

5