Wiring dia gram, Electrical diagrams & tables – Reznor JT4BD Unit Installation Manual User Manual

Page 22

Advertising
background image

22

Figure 13. t4BD Wiring Diagram - Single Phase Models

ElEctrIcal DIagraMS & taBlES

Outdoo

r

F

an Moto

r

R

C

CC

C

H

F

Dual

Capacitor

(Single Phase)

Fi

eld Supply

L1

Gr

d

L2

Groundin

g

Sc

re

w

C

S

T1

T2

L1

L2

HPS

Contac

to

r

R

Star

t

Capacitor

Star

t Rela

y

5

2

hti

w

w

oll

e

Y

hs

a

H

kc

al

B

Comp

Lo

w

Vo

ltag

e

Te

rminal

s

See

Note 6

Defr

ost

Thermostat

TERMINAL OR GR

AY

WIR

E

OD

T(Selec

t

Models Only

)

T2

DFT

TES

T

T1

T2

C

Y

O

W2

R

DFT

E

C

Y

O

W2

R

E

DF1

DF

2

Black

Black

Reversing

V

alv

e

Solenoid

S

CC

Defrost C

ontrol Boar

d

1

CC

H

Black

Red or Red Black

Ye

llow or

Ye

llow Black

Black

Black or

Black

Whit

e

Orange

Re

d

Re

d

Ye

llow

Blac

k

Blue

Y

ello

w

Black

Blac

k

Black

Blue

Black

Yellow

es

a

h

P

el

g

ni

S

)

n

oit

c

e

S r

o

o

dt

u

O(

p

m

u

P t

a

e

H

m

et

s

y

S t

il

p

S

WIRING DIA

GRAM

NO

TES:

1. Disconnec

t all power be

fo

re ser

vicing

.

2. F

or supply connec

tions use copper condu

ct

ors only

.

3. Not suitable on systems that ex

ceed 150 volts to ground

4. F

or replacement wires use condu

ct

ors suitable f

or 105˚ C.

5. F

or ampacities and overcurrent protec

tion, see unit rating plate

.

6. Connec

t to 24 vac/40va/class 2 circuit. See furnace/air handler

installation instruc

tions f

or control circuit and optional

relay/transf

ormer

ki

ts

.

Defrost Board Operation:

Closing during defrost.R

ating: 1 Am

p.

Max.

Opens during defrost.

Ra

ting: 2HP at 230

Va

c Max.

W

ith DFT closed and

“Y

closed, compressor run

time is accumulated. Opening of DFT during

defrost or inte

rv

al period resets the inte

rv

al to 0.

CC

- Contac

tor Coil

CC

H - Crankcase Heater

DFT - Defrost

Thermostat

HPS - High

Pr

essure Switch

R

VS - Reversing

Va

lve Solenoi

d

* - Hard Sta

rt

Kit

Fi

eld Installed

OD

T - Outdoor

Thermostat

1. Couper le courant avant de faire letretien.

2. Employez uniquement des conduc

teurs en cuivr

e.

3. Ne con

vient pas aux installations de plus de 150 volt a la terr

e.

710507-D

(Replaces 710507

-C

)

05/11

FIELD

WIRING

LEGEND:

LO

W

VOL

TA

GE

HIGH

VOL

TA

GE

Dual

C

apacitor

H

C

F

CC

H

C

ompr

essor

Co

ntac

ts

C

ompr

essor

Outdoor F

an Moto

r

R

C

S

L1

T1

L2

T2

E

Defrost

Co

ntr

ol

Boar

d

DF

T

OD

T (Selec

t

Models Only)

Co

ntro

l

Lo

gi

c

DF

1

DF

2

DFT

1

2

3

1

2

3

4

4

1

R

W2

O

Y

C

T2

T1

R

W2

O

Y

C

RV

S

HPS

208/230V

CC

R

C

S

Advertising