Wiring dia gram, Single phase – Reznor JT4BD Unit Installation Manual User Manual

Page 23

Advertising
background image

23

Outdoor

F

an Motor

CC

C

H

F

Dual

Capacitor

(Single Phase)

Field Supp

ly

L1

Gr

d

L2

Gr

ounding

Scre

w

C

S

R

C

Y

Comf

or

t

Aler

t

T1

T2

L1

L2

LPS

HPS

Used in R410a Models Onl

y

Contactor

R

Star

t

Capacitor*

Star

t Rela

y*

5

2

Blac

k

hti

w

w

oll

e

Y

h

s

a

H

k

c

al

B

Comp

Orang

e

Lo

w

Vo

ltag

e

Te

rminal

s

See

Note 6

Red

Red

Defr

ost

Thermosta

t

T2

DFT

TEST

T1

T2

C

Y

O

W2

R

DFT

E

C

Y

O

W2

R

E

DF1

DF

2

Blac

k

Blac

k

Re

ve

rs

ing

Va

lv

e

Solenoid

Ye

ll

ow

CC

w

oll

e

Y

Black

Blue

Blac

k

Defr

ost Cont

ro

l Boar

d

Ye

llo

w

1

CCH

Yellow

L

L

Select

Models

On

ly

Bla

ck

Blue

Blac

k

R

C

S

Bla

ck

Blac

k

Ye

ll

ow

Bla

ck

Ye

ll

ow

Red

WIRING DIA

GRAM

710533E

(Replaces 710533D)

06/10

Status LED

Status LED Description

Green "POWER"

Module has power

Red "TRIP"

Thermostat demand signal Y is present,

but the compressor is not running

Yellow "ALERT" Flash Code 1

Long Run Time

Compressor is running extremely long

run cycle

Yellow "ALERT" Flash Code 2

System Pressure Trip

Discharge or suction pressure out of

limits or compressor overloaded

Yellow "ALERT" Flash Code 3

Short Cycling

Compressor is running only briefly

Yellow "ALERT" Flash Code 4

Locked Rotor

Yellow "ALERT" Flash Code 5

Open Circuit

Yellow "ALERT" Flash Code 6

Open Start Circuit

Current only in run circuit

Yellow "ALERT" Flash Code 7

Open Run Circuit

Current only in start circuit

Yellow "ALERT" Flash Code 8

Welded Contactor

Compressor always runs

Yellow "ALERT" Flash Code 9

Low Voltage

Control circuit < 17 VAC

CCH

1.

Disconnect all po

wer bef

ore servicing.

2.

For supp

ly

connections use copper conductor

s onl

y.

3.

Not suitable on systems that e

xceed 150 v

olts to gr

ound.

4.

For replacement wires use conductor

s suitable

fo

r 105° C.

5.

For ampacities and

ov

er

current pr

otection,

see unit rating plate

.

6.

Connect to 24 v

ac/40v

a/c

lass 2 cir

cuit.

See furnace/air handler installation

Single Phase

Split System Heat Pump (Outdoor Section)

Legend

Field

Wiring

Fa

ctory

Wiring:

Lo

w

Vo

ltage

High

Vo

ltage

NO

TES:

1.

Couper le courant

av

ant de faire letretien.

2.

Empl

oy

ez uniquement des conducteur

s en cuivr

e.

3.

Ne con

vient pas aux installations de plus de 150 v

olt a la terre

.

instructions f

or contr

ol cir

cuit and optional rela

y/transf

ormer kits

.

1

2

3

4

Dual

Capacito

r

H

C

F

Compressor

Contact

s

Compressor

Outdoor F

an Motor

R

C

S

L1

T1

L2

T2

Lo

w

Vo

ltag

e

Te

rminal

s

E

Defr

ost

Cont

ro

l

Boar

d

DF

T

Cont

ro

l

Logic

DF

1

DF

2

DF

T

1

2

3

4

1

R

W2

O

Y

C

T2

T1

R

W2

O

Y

C

RV

S

CC - Contactor Coi

l

CCH - Crankcase Heater

DFT - Defr

ost

Thermostat

HPS - High Pressure Switc

h

LPS - Lo

w Pressure Swit

ch

RV

S - Re

ve

rs

ing

Va

lve Solenoi

d

* - Har

d Star

t Kit Field Installed

Closing during defr

ost.

Rating:

1 Amp

. Max.

Opens during defr

o

st.

Rating:

2 HP at 230

V

ac Max.

Closed when "Y" is on

. Open when "Y" is of

f.

Pr

ov

ides "off" dela

y time of 5 min

. when "Y" opens

.

With DFT

cl

osed and "Y" c

losed

, compressor run

time is accum

ulated.

Opening of DFT durin

g

defr

ost or interv

al period resets the inter

va

l to 0.

Defr

ost Boar

d Operation:

HPS

LPS

2

08/230V

Y

C

R

L

Comf

or

t

Aler

t

CC

Select

Models Onl

y

L

R

C

S

¢710533z¤

Figure 14. t4BD Wiring Diagram - Single Phase Models with comfort alert

Advertising