LED Test and Status Indicators

9/24/01

12-13

SNMP Control Panel. Setting this switch to the Alarm Cut-Off position (ON) opens the alarm relay
contacts (150 Vrms, 150 mA maximum load) that close when the Access Bank II - SNMP enters an
alarm state.
Table 9-3 defines the pin functions on the 50-pin Tip & Ring jack.

Table 12-3: 50-Pin Tip & Ring Jack

12.11 LED Test and Status Indicators

Five test and status LED indicators on the Access Bank II - SNMP Control Panel provide a visual
means of identifying system, T1 line and V.35 interface troubles.

Table 12-4: T1 Line Status LEDs for T1 Span 1 and T1Span 2

Pin Location

Function

26
1

Tip Channel 1
Ring Channel 1

27
2

Tip Channel 2
Ring Channel 2

49
24

Tip Channel 24
Ring Channel 24

50
25

Alarm Tip Channel 25
Alarm Ring Channel 25

State

Meaning

OFF

Loss of T1 signal, no pulses received.

GREEN

Access Bank II - SNMP is in frame
with a frame-bit error rate <10E-5.

FLASHING GREEN

Access Bank II - SNMP is in frame,
but frame-bit error rate exceeds 10E-
5.

RED

AIS (Unframed All Ones Signal)
received from the incoming T1 span.

FLASHING RED

Access Bank II - SNMP is not syn-
chronized to the incoming T1 line,
but no AIS is being received.

YELLOW

BPV errors received on the T1 line
that are not due to B8ZS line coding.

FLASHING YELLOW

Yellow Alarm received from the T1
line.